Welcome to visit The Chinese Journal of Process Engineering, Today is
Reaction and Separation

Removal of As(III) from Ground Water by Plate Electrode Method

  • LIANG Feng ZOU Guo-fang ZHU Hui-jie WANG Hong-qiang ZHANG Ya-chao WANG Nuo-ya HE Huan
Expand
  • 1. School of Municipal and Environmental Engineering, Henan University of Urban Construction
    2. School of the Environment, Nanjing University
    3. Pingdingshan Comprehensive Utilization and Environmental Protection Institute

Received date: 2016-02-02

  Revised date: 2016-04-04

  Online published: 2016-10-14

Abstract

The arsenite removal from the simulated groundwater was studied by the plate graphite electrode electric adsorption. We investigated that the effects of the ionic strength, the initial arsenite concentration, the distances between the two plate electrode, and the voltage on the arsenite removal efficiency. The experimental results showed the arsenite removal efficiency reached up to 99.4% by the graphite electrode when the ionic strength is 0.1 mol/L NaCl, the voltage is 2.5 V, the distances between the two plate electrode is 3 cm, the electric adsorption time is 60 min. The water quality after electric adsorption approximates national standard of drinking water. The arsenite removal was 98.4%?99.2% in the 8 cycles of electrosorption/electrodesorption of arsenic, furthermore, the graphite electrode showed the higher performance after the regeneration.

Cite this article

LIANG Feng ZOU Guo-fang ZHU Hui-jie WANG Hong-qiang ZHANG Ya-chao WANG Nuo-ya HE Huan . Removal of As(III) from Ground Water by Plate Electrode Method[J]. The Chinese Journal of Process Engineering, 2016 , 16(5) : 751 -756 . DOI: 10.12034/j.issn.1009-606X.216131

Outlines

/