Welcome to visit The Chinese Journal of Process Engineering, Today is
Process & Technology

Anti-scaling Method and Process Optimization in the Advanced Treatment of Mine Water

  • Jianjun LIU Yanchun ZHANG Rongji LI Sen WANG Binqi WANG
Expand
  • 1. Yongcheng Kaikong Water Affairs Co., Ltd., Yongcheng, Henan 476600, China; 2. Beijing Secolever Environmental Science Co., Ltd., Beijing 102208, China; 3. College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China

Received date: 2017-01-03

  Revised date: 2017-02-21

  Online published: 2017-10-10

Abstract

According to the process and site conditions of the Yongcheng Kaikong reuse mine water project, it was suggested to control the hardness, regulate pH, select the reasonable rate of recovery and optimize the choice of antiscalant after theoretical analysis, calculation and experimental study. The optimal conditions for a safe and economical reverse osmosis system were calcium concentration lower than 160 mg/L, pH equal to 7.4, antiscalant dosage 2.8?10?6(?). The results of three-year running showed that the scaling problem has been effective controled, and the pressure difference and the desalination rate have undergone little change.

Cite this article

Jianjun LIU Yanchun ZHANG Rongji LI Sen WANG Binqi WANG . Anti-scaling Method and Process Optimization in the Advanced Treatment of Mine Water[J]. The Chinese Journal of Process Engineering, 2017 , 17(5) : 1011 -1015 . DOI: 10.12034/j.issn.1009-606X.217103

Outlines

/