Aiming at the residue-to-chemicals (RTC) technology for enhanced light olefin production, and in consideration of its unique reactor structural characteristics, a cold-flow model experimental setup comprising a riser and an inverted cone-shaped fast fluidized bed reactor was established. Within the fast fluidization regime, differential pressure transmitters and fiber-optic particle concentration probes were employed to measure the axial and radial distribution patterns of solid holdup in the inverted cone-shaped fast fluidized bed reactor under different superficial gas velocities and solid circulation rates. The results show that, within the operational range of superficial gas velocities from 2.39 to 3.35 m/s and solid circulation rates from 16.38 to 46.74 kg/(m2?s), the axial solid holdup exhibited a "dilute at the top, dense at the bottom" distribution pattern, while the radial solid holdup displayed a core-annulus structure with higher concentrations near the wall and lower concentrations at the center. As the solid circulation rate increased or the superficial gas velocity decreased, the average solid holdup in the reactor increased, and the non-uniformity of particle distribution intensified. At a particle circulation rate of 15 kg/(m2?s), as the superficial gas velocity increases from 2.39 m/s to 3.35 m/s, the axial non-uniformity index ANI(εs) decreased from 0.661 to 0.378. At an axial height of H=3.45 m, as the particle circulation rate increases from 15.18 kg/(m2?s) to 37.04 kg/(m2?s), the radial non-uniformity index RNI(εs) in the dense phase zone of the lower reactor section increased from 0.210 to 0.256. To improve the axial uniformity of particle distribution in the reactor, catalyst particles were replenished in the upper section. After catalyst supplement, the axial non-uniformity index decreased from 0.485 to 0.376, partially alleviating the "dilute at the top, dense at the bottom" distribution defect, while the average solid holdup in the reactor increased from 0.078 to 0.123. Under the operating conditions of the RTC technology with an average superficial gas velocity of 2~3 m/s, the average solid holdup in the inverted cone-shaped fast fluidized bed reactor was approximately 5.66 times higher than that in the riser reactor, providing favorable conditions for enhancing the catalytic cracking efficiency of heavy oil.
WANG Hao
,
GENG Su-Long
,
GONG Jian-Hong
,
ZHANG Tong-Wang
. Experimental study on gas-solid flow characteristics in an inverted cone fast fluidized bed reactor[J]. The Chinese Journal of Process Engineering, 2026
, 26(10)
: 1079
-1089
.
DOI: 10.12034/j.issn.1009-606X.225322