对热风混合器进行了结构改进,采用标准k??模型对改进前后热风混合器内部的流场和温度场分布进行了数值模拟。结果表明,相比于传统结构,对称T型双热风入口结构的混合器内部流场分布对称性较好,气流均匀性提高,渐缩型出口设计改善了回流问题,加设分散挡板增强了换热效果。三方面的结构改进使混合器出口气流的温度均匀性有效改善,减小了能量消耗,提高了热混合效率。
Hot air mixer is a kind of equipment used in heating and drying system for intermediate cooling treatment. The traditional structure of hot air mixer has the problem of uneven distribution of outlet air temperature in industrial application. For this reason, an improved structure of hot air mixer was proposed in this work. The uniformity of flow field and temperature field distribution in hot air mixer before and after improvement was numerically simulated by using standard k?? model. The results showed that, compared with the traditional structure, the symmetry of flow field distribution in the mixer with symmetrical T double hot air inlet structure was better, and the uniformity of flow field was improved. The reverse flow was greatly improved by the tapered outlet design, and the heat transfer effect was enhanced by adding dispersive baffles. The above three structural improvements could effectively improve the temperature uniformity of the mixer outlet gas flow, reduce energy consumption and improve the thermal mixing efficiency, which had great reference value for the engineering design of the hot air mixer.
[1]广州市威士环保科技有限公司.一种热风混合室: 中国, CN201720712761.9 [P]. 2017-12-29.
[2]深圳市泽源能源股份有限公司.调压式热风混合室: 中国, CN201721825901.X [P]. 2018-08-28.
[3]Xiao H W, Gao Z J, Hai L, et al.Air impingement drying characteristics and quality of carrot cubes[J].Journal of Food Process Engineering, 2010, 33(5):899-918
[4]高振江.气体射流冲击颗粒物料干燥机理与参数试验研究 [D]. 中国农业大学, 2000.
[5]王丽红, 高振江, 肖红伟, 林海, 姚雪东.圣女果的气体射流冲击干燥动力学[J].江苏大学学报自然科学版, 2011, 32(05):540-544
[6]扬州市恒通环保科技有限公司.一种混风加热装置: 中国, CN201620696973.8 [P]. 2017-02-22.
[7]Khatchatourian, O.A.,Vielmo,HA.,Bortolaia,L. A..Modelling and simulation of cross flow grain dryers[J].Biosystems Engineering, 2013, 116(4):335-345
[8]昆明理工大学.一种热风混合流立式干燥器: 中国, CN201620053085.4 [P]. 2016-08-24.
[9]王健,董继先,王栋,等.果蔬干燥箱气流分配室的数值模拟与结构优化[J].陕西科技大学学报, 2019, 37(1):128-134
[10]田松涛,高振江.基于的气体射流冲击烤箱气流分配室改进设计[J].现代食品科技, 2009, 25(6):612-616
[11]代建武, 肖红伟, 白竣文, 张茜, 谢龙, 高振江.气体射流冲击干燥机气流分配室流场模拟与结构优化[J].农业工程学报, 2013, 29(03):69-76
[12]董继先, 王文茹.果蔬干燥设备的数值分析与设计[J].食品工业, 2017, 38(03):183-185
[13]张伟,严平.热风干燥烘房气流速度场均匀性优化[J].轻工机械, 2019, 37(01):83-87
[14]杨先亮,郜坤,戎瑞,等.谷物干燥塔内气流组织模拟及结构优化[J].科学技术与工程, 2018, 18(33):19-29
[15]于洋,李若兰,夏治新,等.热风式枸杞烘干机烘干室结构优化及流场分析[J].农机化研究, 2019, 41(09):214-221
[16]梁航.合成革烘箱内循环风入口方向对温度场的影响分析 [J]. 化学工程与装备, 2017(12): 221-224+230.[J].化学工程与装备, 2017, 46(12):221-224
[17]秦卫伟,胡传波,文怀兴,等.旋转闪蒸干燥设备结构设计及流场分析[J].食品工业, 2018, 39(03):220-226
[18]王少丹,钱珊珠,田伟娜,等.紫花苜蓿太阳能干燥箱的设计及模拟[J].农机化研究, 2018, 40(11):246-250
[19]佛山赛因迪环保科技有限公司.一种防冲壁对称式双入口吸收塔: 中国, CN201721294936.5 [P]. 2018-04-24.
[20]王端,李志鹏,高正明,等.型撞击流混合器内流动特性的研究[J].过程工程学报, 2010, 10(04):638-643
[21]钟建平.回流燃烧室排气弯管造型与结构设计 [C].// 中国航空学会动力专业分会燃烧与传热传质专业委员会2000年学术年会论文集.北京: 2000:248-251, 255.
[22]代建武,杨洋,张黎骅,等.一种扰流式气流均匀分配室 [P]. 中国专利: CN206420290U, 2017-08-18.
[23]中国科学院工程热物理研究所.一种具有射流冲击作用的扰流挡板强化传热装置: 中国, CN200810112427.5 [P]. 2009-11-25.