Reasonable Aeration Tap Setting of Burned Oil Sand Particles in Standpipe of a Fluidized Bed

  • 王子健 曹鑫 卢春喜
展开
  • 中国石油大学(北京)化工学院 中国石油大学(北京)化工学院 石油大学(北京)重质加工国家重点实验室

收稿日期: 2015-06-08

  修回日期: 2015-07-02

  网络出版日期: 2015-10-20

Reasonable Aeration Tap Setting of Burned Oil Sand Particles in Standpipe of a Fluidized Bed

  • WANG Zi-jian CAO Xin LU Chun-xi
Expand
  • College of Chemical Engineering, China University of Petroleum(Beijing) College of Chemical Engineering, China University of Petroleum(Beijing) State Key Laboratory of Heavy Oil, China University of Petroleum (Beijing)

Received date: 2015-06-08

  Revised date: 2015-07-02

  Online published: 2015-10-20

摘要

A large scale cold model apparatus of CFB riser reactor was established according to the method of directly fluidized coking oil sand. By changing the position of aeration orifice and amount of aeration air, the solids flux was measured and the location of sensitive aeration orifice above a butterfly valve was fixed (50 mm above the valve). At last, the amount of aeration air for allocation (1~1.5 m3/h) was known and the distance between each pair of consecutive general aeration orifices (about 3 m). And a prediction equation for estimating the relation between the amount of aeration air and the solids flux was established based on experimental data and theoretical analysis, which was Q=6.17Ws0.8529(D/Do)2(L/Lo). The prediction was in good agreement with the experimental data. By using a multi-point pressure pulsation instrument to measure the pulsation at different altitudes of the standpipe, the pressure pulsation curves at different aeration orifices under different amounts of aeration air were drawn. By Fourier transformation, it was found that there was no obvious dominant frequency when oil sand flowed through the circulation standpipe, and each frequency seemed to make equal contribution to the pressure pulsation. The periodical concentration fluctuation of the particles did not exist in the circulating standpipe, and the pulsation intensity was small.

本文引用格式

王子健 曹鑫 卢春喜 . Reasonable Aeration Tap Setting of Burned Oil Sand Particles in Standpipe of a Fluidized Bed[J]. 过程工程学报, 2015 , 15(5) : 751 -757 . DOI: 10.12034/j.issn.1009-606X.215233

Abstract

A large scale cold model apparatus of CFB riser reactor was established according to the method of directly fluidized coking oil sand. By changing the position of aeration orifice and amount of aeration air, the solids flux was measured and the location of sensitive aeration orifice above a butterfly valve was fixed (50 mm above the valve). At last, the amount of aeration air for allocation (1~1.5 m3/h) was known and the distance between each pair of consecutive general aeration orifices (about 3 m). And a prediction equation for estimating the relation between the amount of aeration air and the solids flux was established based on experimental data and theoretical analysis, which was Q=6.17Ws0.8529(D/Do)2(L/Lo). The prediction was in good agreement with the experimental data. By using a multi-point pressure pulsation instrument to measure the pulsation at different altitudes of the standpipe, the pressure pulsation curves at different aeration orifices under different amounts of aeration air were drawn. By Fourier transformation, it was found that there was no obvious dominant frequency when oil sand flowed through the circulation standpipe, and each frequency seemed to make equal contribution to the pressure pulsation. The periodical concentration fluctuation of the particles did not exist in the circulating standpipe, and the pulsation intensity was small.